AMFLOW® LPI FILTER 

 

OVERVIEW

The LPI Filter is a low pressure filter assembly for pressures up to 275-bar (4,000 PSI) and incorporates a reusable filter element that can be back flushed for cleaning purposes. There are four (4) standard size elements and four (4) special order size elements available from 2.5 Micron up to 100 Micron.  Filter elements may be purchased individually.

 

SPECIFICATIONS

Design Features

  • Ease of Operation
  • Reusable Filter Elements
  • Provision for Back Flushing
  • Variety of Micron Elements
  • Environmentally Sealed

Mechanical Features

  • Standard Construction - Filter Assembly:  316L Stainless Steel
  • Standard Construction - Filter Element:  Five Layered, Dutch Weave, Sintered 316L Stainless Steel
  • Standard Inlet & Outlet Ports:  3/8" BSPP Inlet & Outlet
  • Standard Seals:  FFKM & PTFE
  • Standard Element Sizes: 2.5 micron, 5.0 micron, 10 micron, & 50 micron
  • Special Order Element Sizes:  20 micron, 30 micron, 75 micron & 100 micron 
  • Weight: 1.13 kg (2.5 lbs)  

Operating Environment

  • Operating Temperature: -15oC to 200oC  (5oF to 392oF)
  • ATEX 2 G Ex d T3

 Certification

  • Certification of material type and condition, and all post process, including anodizing, heat treatment, plating, and all chemical processes, will be maintained on file with A & H Enterprises, Inc. for a period of not less than five years.
Filter Housing Restriction =
Flow Rate Restriction 
TBD
Operating Pressure

275 bar
(4000 PSI) 

Hystrostatic Pressure

412 bar
(6000 PSI) 

Filtration Area (Filter Element)  88.06 cm2
(13.65 sq. in)