REPRESENTATIVES

 
NORWAY, SWEDEN, DENMARK, NETHERLANDS, GERMANY, U.K., ITALY
AMFLOW® NORGE   
Prinsens vei 12
4315 Sandnes
Norway

Phone:   +47.922.19.656
Fax:   +47.520.00.591
 Email:   leif.egil.pettersen@amflow.no

 

MALAYSIA, INDONESIA, SINGAPORE, INDIA, THAILAND, VIETNAM
AMFLOW CONTROLS ASIA SDN BHD   
No. 1701, Block 1, TTDI ADINA
Jalan Judo 13/45, Seksyen 13
40675 Shah Alam, Selangor
Malaysia

Phone:   (+603) 5523.8418
Mobil:   (+6012) 3323.118
 Email:   amflowcontrols@gmail.com

 

  

NIGERIA
SUDIFLOW INTERGRATED SERVICES, LTD   
25 Elelenwo Road
Port Harcourt, Nigeria

Phone:   +234.803.309.1405
+705.679.4894
 Email:   sudiflow@yahoo.com

ACTUATOR DD FILES

To download files for the Hart protocol, please click here.

 

COMMUNICATIONS

 The next generation of embedded communication systems, offers the diversity of a mother-daughter board design allowing the option of differing interchangeable communication system modules.

All of Amflow electronic valve actuators, have the 4-20mA and Industrial Ethernet communication capabilities on the motherboard for remote automation control.  Optional daughter boards are available with either H1, a FOUNDATIONTM fieldbus registry, HART, or Modbus RTU, TPC communication modules. 

Software Features

  • Bootloader support for firmware upgrades
  • Motherboard (Industrial Ethernet and 4-20mA) with interchangeable daughter boards:
    >  FOUNDATIONTM fieldbus H1 Module
     HART 
         >  Modbus RTU, Modbus TCP
    Valve Position control including overshoot and return
    >  Ensures valve is always opened or closed from same direction
  • Motor Current monitor
    >  Determines starting torque and running torque on valve
  • Module detect
    >  Configures web page based on attached module
  • Non-volatile storage of user settings
  • Embedded Web Server for access to control Web Page

Embedded Web Page Features

  • Communication strobe
  • Network configuration of device
  • Firmware upgrade
  • MAC address display of device
  • Valve configuration settings:
    >  Belt or Direct Drive option 
    >  Motor Direction
    >  Valve Turns
    >  Belt Ratio
    >  Power On Response (Find zero or hold)
    >  Motor Speed
    >  Valve Span Max
    >  Valve Span Min
    >  Over Torque Response (retry or cancel)
    >  Fault Timeout (seconds)
    >  Start Torque Limit
    >  Run Torque Limit
  • Direct Valve Position Control
  • Monitor Valve Position Plot and % Value Diplay
  • Motor Torque monitoring
  • Motor Speed monitoring
  • Find Zero (home position) Command
  • Stop Motor (cancels any current movement)
  • Fault monitoring (fault # and timeout countdown)
  • Module monitoring including signals, 4-20mA, etc.
  • Help Page to explain page functionality