AMFLOW® AM8C FLOW CONTROL VALVE



AM8C Flow Control Valve
OVERVIEW

For chemical injection applicatons requiring a range of flow rates from 1.00 LPH up to 600 LPH, the ATEX-certified AM8C Flow Control Valve features our patented Dual Piston technology.  The AM8C is pressure independent for reliable metering across a wide range of chemicals.  This self-regulated design provides a standard turndown ratio of up to 50:1, with repeatablity and accuracy within  ± 3% full range.  The AM8C is able to pass 1.00 mm particles, making it suitable for chemical injection applicatons with some debris in the process line.  The AM8C may be combined with any of Amflow's Electronic Actuators. 

SPECIFICATIONS

Design Features

  • Low Maintenance
  • 50:1 turndown ratio 
  • Maximum panel thickness: 7mm (0.28”)
  • Mounting hole diameter: 35mm (1.38”)
  • Low torque requirements for adjustment 
  • Environmentally Sealed

Mechanical Features

  • Construction 316L Stainless Steel 
  • Componenets:  Ceramic for high pressure control
  • Inlet & Outlet Ports:  1/2" FBSPP
  • Purge Port:  1/8" BSPP
  • Seals:  FFKM & PTFE
  • Weight: 6.8 kg (15 lbs)

Operating Environment

  • Operating Temperature: -15oC to 200oC  (5oF to 392oF)
  • ATEX 2 G Ex d T3

Certification

  • Certification of material type and condition, and all post process, including anodizing, heat treatment, plating, and all chemical processes, will be maintained on file with A & H Enterprises, Inc. for a period of not less than five years.
 Standard
Minimum H2O
Standard
Maximum H2O
Flow* 1.00 LPH 600 LPH
Flow* with Methanol 1.00 LPH 750 LPH
Operating Pressure**  20-bar (300 PSI) 414-bar (6,000 PSI)
Hydrostatic Pressure Test 620-bar
(9,000 PSI)
Turndown Ratio up to
50:1
 


    * Depending on characteristics of the media
  ** Inlet Pressure.  Minimum recommended pressure supplied by pump to valve 
*** Turndown Ratio can vary dependent upon chemical composition, flow rate, and ∆p